Technical Documentation “Instreamer “ - V4.03 - 24th October 2013
4 Hardware and Connectors
4.1 Green and Red LEDs
Two status LEDs provide information on the current device operation.
No Application loaded (only bootloader) or started with hold reset button during power up
• The green LED is on and
• The red LED blinks.
Application starts (Barix boot-up sequence)
• First the red goes on and
• The green LED blinks once.
If no IP address is configured, then during DHCP:
• The red LED blinks with a continuous cycle.
• The green LED blinks five times and then pause four times.
If an error is detected:
• The red LED remains on and
• the device resets itself after the green LED has indicated the error as follows:
Error Green LED blinks
Corrupt application or IP address conflict five times.
The Network hardware could not be initialized or a Corrupt MAC address three times.
Application is running:
• The red LED is off
• On stop (not sending) the green LED is on.
• On sending the green LED blinks slowly.