Technical Documentation “Instreamer “ - V4.03 - 24th October 2013
2.11 Setup
The factory default setup is contained in the binary file config.bin. This file can be edited with a hex editor. Be careful if you do changes. This file will
be loaded to the EEPROM on factory default.
General Terms (EEPROM Organization)
IP addresses are always stored with the highest byte at the lowest address.
Strings are coded in ASCII and terminated with 0x00. The Length includes the termination.
Values are stored in little endian format (Intel) (low byte first)
All Values are integer.
Signed values are stored in 2-complement.
Unused bytes must be set to 0x00.
In the following table the column Byte shows the byte number in the 1016 bytes of configuration. The first byte has the number 0.
If a password is set then the device only will answer to this commands if the password in the command is set correct.
Parameter Byte
[dec]
Dyn.
Name
Length
[Byte]
Default
Value
Short Description
Own IP 0 B0, B1,
B2, B3
4 0.0.0.0 Static IP address of the device. 0.0.0.0 for DHCP.
0.0.1.0 disable AutoIP
0.0.2.0 disable DHCP
0.0.4.0 disable BOOTP
0.0.8.0 disable IPzator
add this special IP addresses for disabling multiple protocols
Gateway IP 4 B4, B5,
B6, B7
4 0.0.0.0 Gateway IP address. 0.0.0.0 for no gateway
Netmask 8 N8B0,
N8B1,
N8B2,
N8B3
1 0 Subnetmask. The value is the count of the zero bits counted from the lowest byte. (ex. 8
for 255.255.255.0)
IFMODE0 80 B80b0-1,
B80b2-3,
B80b4-5,
B80b6-7
or B80
1 0x4C Definition of the bits in that byte for the serial port 0:
15 Software Application Interface Software Application Interface 15