7.8 Control settings
These settings adjust the control ports, IR source and IR
gateway properties.
UDP command port
Define the port on which the device will receive commands
via UDP.
TCP command port
Define the port on which the device will receive commands
via TCP.
Web server port
Defines the port where the webserver of the Barix
Exstreamer can be reached. If set to
"0"
the default HTTP
port (80) is used.
IR Source
Always select "IR Serial Dongle". "IR IN" is non functional.
IR Gateway
When activated all received IR remote control commands
will be transmitted to other Barix devices IR OUT output.
Leaving the IP address at 0.0.0.0 and setting a valid port
(not 0) will broadcast the IR commands in the LAN.
To direct to a specific device set the IP Address of the
device and the port (
Example: 192.168.0.24:12301
).
To disable the IR Gateway set the IP address to 0.0.0.0 and
the port to 0.
7.9 Serial settings
This settings adjust the serial port, serial gateway and IR
Dongle LED properties.
Baud rate
Select the serial transmission speed (300 to 115200 Baud).
Data bits
Select 7 or 8 data bits.
Parity
Select no, even or odd parity.
Stop bits
Select 1 or 2 stop bits.
Flow control
Select the type of flow control:
none, software (XON/XOFF) or hardware (RTS/CTS).
Local port
Defines the port on which the serial port can be accessed
for serial gateway application. Only when "Local port" is set
to "0" the serial port can be used as a command interface.
If the active serial gateway is enabled and the "Local port" is
set to a value then this will be the source port of the TCP
connection. On
"0"
a random source port is used.
Destination IP
To have this Barix Exstreamer actively establish a serial
gateway select the destination IP address to the device
where the serial data will be transmitted to (and received
from).Select "0.0.0.0" when the serial port is only used
local.
Destination port
Defines the port for the active serial gateway function (see
destination IP).
Notes
Both settings, "Destination IP" and "Destination port" have
to be set to enable the gateway function.
RTS function
Select the function of the RTS output pin.
On "IR Status" the LED on the connected IR Dongle will
flash upon reception of an IR Remote Control (default
setting). On "activate AVR" RTS is on during streaming and
60 sec after the last streaming. It can be used to activate an
Audio Video Receiver or Amplifier. On "RTS" it can be
used for flow control as usual or as an additional output.